Sign In | Join Free | My himfr.com
Home > Molded Case Circuit Breaker >

160A Double Molded Case Circuit Breaker / Four Pole Adjustable Circuit Breaker

    Buy cheap 160A Double Molded Case Circuit Breaker / Four Pole Adjustable Circuit Breaker from wholesalers
     
    Buy cheap 160A Double Molded Case Circuit Breaker / Four Pole Adjustable Circuit Breaker from wholesalers
    • Buy cheap 160A Double Molded Case Circuit Breaker / Four Pole Adjustable Circuit Breaker from wholesalers

    160A Double Molded Case Circuit Breaker / Four Pole Adjustable Circuit Breaker

    Ask Lasest Price
    Brand Name : KRIPAL
    Model Number : UKM32-160/4
    Certification : CE, KEMA
    Price : negotiable
    Payment Terms : T/T, L/C
    Supply Ability : 50000 pcs per month
    Delivery Time : 20 days and depends on ordering quantity
    • Product Details
    • Company Profile

    160A Double Molded Case Circuit Breaker / Four Pole Adjustable Circuit Breaker


    160A Double Molded Case Circuit Breaker / Four Pole Adjustable Circuit Breaker


    KRIPAL has the Utility Model Patent for the structure of double making & double breaking!


    The UKM32 series MCCB are used for making, breaking, and protection of low-voltage distribution systems and motors. Several breaking capacities exist for each model of circuit breaker, meeting

    the demands for varying types of protection. Several different rated current levels are available for

    each frame size


    Model

    Rated current (A)

    UKM32-160

    16

    20

    25

    32

    40

    50

    63

    80

    100

    125

    160

    UKM32-250

    40

    50

    63

    80

    100

    125

    160

    200

    250

    -

    -

    UKM32-630

    300

    400

    500

    630

    -

    -

    -

    -

    -

    -

    -


    Description:


    1. Thermal magnetic adjustable
    2. Double making & double breaking design
    3. Contacts: 85% AgCdo
    4. Metal parts: cooper
    5. Plastic Parts: brand-new materials

    6. High breaking capacity.

    7. Bearing Rotating shaft

    8. The max breaking capacity of each model is up to 150 kA
    9. U-type fixed contact design
    10. Don't contain any noxious substances and its manufacturing And processing are performed in accordance

    with the requirements of ISO14001.


    Specifications:


    MCCBs for power distribution

    UKM32-160

    UKM32-250

    UKM32-630

    Frame size

    160

    250

    630

    Rated current, In

    16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 160

    40, 50, 63, 80, 100, 125, 160, 200, 250

    300, 400, 500, 630

    Poles

    3, 4,

    3, 4,

    3

    Rated operational Voltage, Ue

    AC (V)

    690

    690

    690

    DC (V)

    500

    500

    500

    Rated impulse withstand voltage, Uimp

    8

    8

    8

    Rated insulation voltage. Uimp

    750

    750

    750

    Rated ultimate short circuit breakering capacity, Icu

    N

    N

    N

    AC 50/60HZ

    220/240V (KA)

    85

    100

    100

    380/415V (KA)

    50

    85

    65

    440/460V (KA)

    50

    70

    65

    480/500V (KA)

    30

    50

    42

    660/690V (KA)

    5

    8

    10

    DC

    250V (KA)

    42

    65

    50

    2 poles in series

    500V (KA)

    42

    65

    50

    Rated service breaking capacity, Ics(%Icu)

    100%

    100%

    100%


    Current-limiting Capacity:


    Current limiting means the limiting increase of the short circuit current in a circuit. In a circuit protected
    by the UKM32 product series, both the peak value and energy l2t of the short circuit current generated
    are far less than expected.


    A. U -Type fixed contact design


    The pre-breaking technique may be realised by means of a unique U-Type fixed contact.
    The pre-breaking technique refers to that of the electrodynamic force generated throuth the U-Type
    fixed contact and that wnich occurs on moving contact system. The higher the short circuit current,
    the bigger the repulsive electrodynamic forces they generate simultaneously. Prior to releasing,
    the electrodynamic repulsive forces may separate the moving contact from the fixed contact, and the
    equivalent resistance between these two contacts is increased by streching the electrical arc.


    B. Double making & double breaking design


    The current-limiting function of the pre-breaking technique is enhanced because of increase in instantaneous arc resistance and arc voltage and a fast drop in the current increase rate.
    Reduces the damage and loss of equipment and the power lines caused by a short circuit current,