Sign In | Join Free | My himfr.com
Home > Molded Case Circuit Breaker >

160A 4 P 50KA Molded Case Circuit Breaker , Moulded Case Circuit Breaker KEMA Certified

    Buy cheap 160A 4 P 50KA Molded Case Circuit Breaker , Moulded Case Circuit Breaker KEMA Certified from wholesalers
     
    Buy cheap 160A 4 P 50KA Molded Case Circuit Breaker , Moulded Case Circuit Breaker KEMA Certified from wholesalers
    • Buy cheap 160A 4 P 50KA Molded Case Circuit Breaker , Moulded Case Circuit Breaker KEMA Certified from wholesalers
    • Buy cheap 160A 4 P 50KA Molded Case Circuit Breaker , Moulded Case Circuit Breaker KEMA Certified from wholesalers
    • Buy cheap 160A 4 P 50KA Molded Case Circuit Breaker , Moulded Case Circuit Breaker KEMA Certified from wholesalers
    • Buy cheap 160A 4 P 50KA Molded Case Circuit Breaker , Moulded Case Circuit Breaker KEMA Certified from wholesalers

    160A 4 P 50KA Molded Case Circuit Breaker , Moulded Case Circuit Breaker KEMA Certified

    Ask Lasest Price
    Brand Name : KRIPAL
    Model Number : UKM32-160/4
    Certification : CE, KEMA
    Price : negotiable
    Payment Terms : T/T, L/C
    Supply Ability : 50000 pcs per month
    Delivery Time : 15 days and depends on ordering quantity
    • Product Details
    • Company Profile

    160A 4 P 50KA Molded Case Circuit Breaker , Moulded Case Circuit Breaker KEMA Certified


    Ics=Icu 160A 4 P 50KA Moulded Case Circuit Breaker KEMA certified


    KRIPAL has the Utility Model Patent for the structure of double making & double breaking!


    The UKM32 series MCCB Thermal magnetic Molded Case circuit Breakers, which are the type found in most distribution boards, incorporate both techniques with the electromagnet responding instantaneously to large surges in current (short circuits) and the bimetallic strip responding to less extreme but longer-term over-current conditions. The thermal portion of the circuit breaker provides an "inverse time" response feature, which trips the circuit breaker sooner for larger overcurrents but allows smaller overloads to persist for a longer time. On very large over-currents during a short-circuit, the magnetic element trips the circuit breaker with no intentional additional delay.


    Description:


    1. Thermal magnetic adjustable
    2. Double making & double breaking design
    3. Contacts: 85% AgCdo
    4. Metal parts: Cooper
    5. Plastic Parts: brand-new materials

    6. High breaking capacity.

    7. Bearing Rotating shaft

    8. The max breaking capacity of each model is up to 150 kA
    9. U-type fixed contact design
    10. Don't contain any noxious substances and its manufacturing and processing are performed in

    accordance with the requirements of ISO14001.


    Specifications:


    MCCBs for power distribution

    UKM32-160

    UKM32-250

    UKM32-630

    Frame size

    160

    250

    630

    Rated current, In

    16, 20, 25, 32, 40, 50, 63, 80, 100, 125, 160

    40, 50, 63, 80, 100, 125, 160, 200, 250

    300, 400, 500, 630

    Poles

    3, 4,

    3, 4,

    3

    Rated operational Voltage, Ue

    AC (V)

    690

    690

    690

    DC (V)

    500

    500

    500

    Rated impulse withstand voltage, Uimp

    8

    8

    8

    Rated insulation voltage. Uimp

    750

    750

    750

    Rated ultimate short circuit breakering capacity, Icu

    N

    N

    N

    AC 50/60HZ

    220/240V (KA)

    85

    100

    100

    380/415V (KA)

    50

    85

    65

    440/460V (KA)

    50

    70

    65

    480/500V (KA)

    30

    50

    42

    660/690V (KA)

    5

    8

    10

    DC

    250V (KA)

    42

    65

    50

    2 poles in series

    500V (KA)

    42

    65

    50

    Rated service breaking capacity, Ics(%Icu)

    100%

    100%

    100%


    Current-limiting Capacity:


    Current limiting means the limiting increase of the short circuit current in a circuit. In a circuit protected
    by the UKM32 product series, both the peak value and energy l2t of the short circuit current generated
    are far less than expected.


    A. U -Type fixed contact design


    The pre-breaking technique may be realised by means of a unique U-Type fixed contact.
    The pre-breaking technique refers to that of the electrodynamic force generated throuth the U-Type
    fixed contact and that wnich occurs on moving contact system. The higher the short circuit current,
    the bigger the repulsive electrodynamic forces they generate simultaneously. Prior to releasing,
    the electrodynamic repulsive forces may separate the moving contact from the fixed contact, and the
    equivalent resistance between these two contacts is increased by streching the electrical arc.


    B. Double making & double breaking design


    The current-limiting function of the pre-breaking technique is enhanced because of increase in instantaneous arc resistance and arc voltage and a fast drop in the current increase rate.
    Reduces the damage and loss of equipment and the power lines caused by a short circuit current,
    improves the safety, and cuts down on the cost of a secondary protection device.


    FAQ:


    A. How's the delivery time?
    Depend on your quantity, usually within 20days after receiving deposit


    B. Would you accept OEM/ODM service?

    Glad to say that there is planning department, technical department and mould tooling center in our factory. For the OEM & ODM, it is ok for us if your brand, market shares are great.


    C. Would you offer free sample?

    Samples are freely provided and shipping costs is paid on your end usually.


    D What's your guaranty time?

    At least 2 years and depend the product


    E What's your payment term?

    T/T, L/C; other terms is negotiable after further check


    Quality 160A 4 P 50KA Molded Case Circuit Breaker , Moulded Case Circuit Breaker KEMA Certified for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Zhejiang KRIPAL Electric Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)